No tag id is returned – ThingMagic M5e-Compact User Manual

Page 208

Advertising
background image

Demo Application

208

Appendix B: Getting Started - Devkit

Send a Boot Firmware command to verify that the application FW is running. If the
boot loader is currently running, then a set command will return a 0x0101 status
code, indicating an invalid OpCode.

The parameter(s) to the set command are invalid. If an invalid parameter is sent, then

a 0x0105 status code is returned, indicating an invalid parameter value.

If the wrong number of data elements is used, then a 0x0100 status code (wrong

number of data) is returned. This could be the result of an ill-formed command, or
accidentally using the wrong OpCode.

No Tag ID is Returned

If the Read Tag ID Single

command returns an error code of 0x0400 (no tag found), then

most likely it is a set up related issue. Check the following items:

The antenna is properly connected to the unit and configured using the Set Antenna

Port

command.

The tag is the right protocol (that is EPC0) and that the protocol has been set using

the Set Current Tag Protocol

command.

Try using a longer timeout, such as 30 seconds, and varying the tag’s location in

relation to the antenna.

It is also possible the tag may be erased or damaged. Without a second “known good”

reader, it is difficult to tell if this is the case. If a “known good” tag is available, try to
read it.