Common Error Messages

212

Appendix C: Error Messages

Solution

Make sure the number of arguments matches the data length.

FAULT_INVALID_OPCODE – 101h

Cause

The opCode received is invalid or not supported in the currently running program
(bootloader or main application) or is not supported in the current version of code.

Solution

Check the following:

Make sure the command is supported in the currently running program.

Check the documentation for the opCode the host sent and make sure it is correct

and supported.

Check the previous module responses for an assert (0x7F0X) which will reset the

module into the bootloader.

FAULT_UNIMPLEMENTED_OPCODE – 102h

Cause

Some of the reserved commands might return this error code.

This does not mean that they always will do this since ThingMagic reserves the right to
modify those commands at anytime.

Solution

Check the documentation for the opCode the host sent to the reader and make sure it is
supported.