ThingMagic M5e-Compact User Manual

Page 145

Advertising
background image

Application Tag Commands

Command Set

145

BlockWrite Command Fields

An example BlockWrite single tag command is:.

Field

Value

Notes

Length

[1 byte]

Number of bytes in the command following the OpCode.

OpCode

0x2D

BlockWrite

Timeout

[2 bytes]

Ignored when used as an embedded command for

Tag Inven-

tory With Embedded Operations

Chip Type

0x00

Standard Gen2 2.0 tags

Tag Singulation Fields

| Select Option

[1 byte]

bit 6 (x1xx xxxx | 0x40) must be set, indicating a 2-byte sub
command follows this byte, and before the remaining

Tag Sin-

gulation Fields

Sub Command

0x00C7

• 0x00C7 - BlockWrite

Access Password

[4 bytes]

The tag’s Access Password for writing to write locked memory

Tag Singulation Fields

| Select [Address,
Data Length, Data]

[n bytes]

The remaining fields from the

Tag Singulation Fields

Note:

Optional depending on the value of Select Option.

WriteFlags

0x00

Reserved for future use.

MemoryBank

[1 byte]

Memory bank who’s data will be erased. Standard Gen2 field
values:

• 0x00 = Reserved

• 0x01 = EPC

• 0x02 = TID

• 0x03 = User

WordPointer

[4 bytes]

Starting, zero-based, 16-bit word address of the MemoryBank
to be written.

WordCount

[1 bytes]

Number of 16-bit words to be written.

Data

[2*WordCount
bytes]

Data to be written

FF

09

2D

03

E8

00

44

00 C7

11

22

33

44

00

00

00

78

08

34

SOH

Length

OpCode

Timeout (ms)

Chip

Type

Option

Sub

Cmd

Access Password

Select Data Address

(bits)

Select
Data
Length
(bits)

Select
Data

Advertising