Set Application Commands

Command Set

157

Set Current Tag Protocol (93h)

To select a protocol, send the Set Current Tag Protocol code to the reader. A table of
valid protocol codes is found in

Get Current Tag Protocol (63h)

. The following example sets

the protocol to GEN2:

Only protocols that are enabled in the reader are available. These protocols are listed in
the version information for the application, described in

Get Boot Loader/Firmware Version

(03h)

.

Note

Changing protocol parameters manually using

Set Protocol Configuration (9Bh)

will maintain their value across changes in the current protocol using

Set

Current Tag Protocol (93h)

. Their values will NOT be reset if the protocol is

reset, only if the module is power cycled or the application firmware is
reloaded by a

Start Bootloader (09h)

followed by a

Boot Firmware (04h)

.

Note

Calling Set Current Tag Protocol will reset the Tag Buffer.

Set Write TX Power (94h)

The Set Write TX Power command sets the default, module-wide, power level to use for
writing to tags. This is necessary because a write operation may require a different RF
power setting than a read command. The format and arguments of this command are
identical to the Set Read TX Power command:

Note

Power settings for individual logical antenna ports specified in

Set Antenna’s

Power and Settling Time

override the value set here.

FF

02

93

00

05

51

7D

SOH

Length

OpCode

Current Protocol

CRC

FF

02

94

09

C4

28

5B

SOH

Length

OpCode

Power in centi-dBm

CRC