Examples, Error status codes – ThingMagic M5e-Compact User Manual

Page 106

Advertising
background image

Application Tag Commands

106

Command Set

Examples

The following example shows an attempt to kill a tag whose EPC
ID=0x112233445566778899AA and whose Kill password=0x11112222:

Note

If the tag’s kill password is set to 0, the protocol does not allow the tag to be
killed. A non-zero kill password must be set (using the

Write Tag Data

command) before the kill command succeeds. The RFU field should be set
to 0.

Error Status Codes

FAULT_MSG_WRONG_NUMBER_OF_DATA – 100h

FAULT_MSG_INVALID_PARAMETER_VALUE - 105h

FAULT_NO_PROTOCOL_DEFINED – 401h

FAULT_AFE_NOT_ON – 405h

FAULT_NO_TAGS_FOUND – 400h

FAULT_PROTOCOL_INVALID_ADDRESS – 409h

FAULT_PROTOCOL_INVALID_KILL_PASSWORD – 40Ch

FAULT_PROTOCOL_KILL_FAILED - 40Eh

FAULT_GEN2 PROTOCOL_OTHER_ERROR - 420h

FAULT_ANTENNA_NOT_CONNECTED – 503h

FAULT_TEMPERATURE_EXCEED_LIMITS – 504h

FAULT_HIGH_RETURN_LOSS – 505h

FF

13

26

03

E8

01

11

11

22

22

00

50

11 22 33 44 55 66 77

88 99 AA

DD

DB

SOH

Length

OpCode

Timeout (ms)

Option

Kill Password

RFU

Select

Data

Length

Select EPC ID

CRC