Application Tag Commands

Command Set

117

Metadata Flags = 0x0001 OR 0x0004 OR 0x0010 = 0x0015

is as follows:

A response contains the following information:

Get EPC and Metadata Response Fields

FF

03

29

00

15

00

97

55

SOH

Length

OpCode

Metadata Flags

Read Options

CRC

Field

Length

Value

SOH

1 byte

0xFF

Length

1 byte

Based on data returned

OpCode

1 byte

0x29

Status

2 bytes

0x0000 for success. Otherwise see

Appendix C: Error Messages

Metadata Flags

2 bytes

Metadata contained in response

Read Options

1 byte

As sent in request

Tag Count

1 byte

Number of tags in response

Read Count

1

1 byte

Tag EPC/Antenna Read Count

RSSI

1

1 byte

Return Signal Strength Indicator

Antenna ID

1

1 byte

Antenna ID, 4 MSBs for TX and 4 LSBs
for RX

Frequency

1

3 bytes

Frequency in kHz

Timestamp

1

4 bytes

RTC Timestamp

RFU

1

2 bytes

Reserved for Future Use - ThingMagic
Only

Protocol ID

1

1 byte

Protocol ID of tag read (always 0x05 for
M5e/M5e-C)

Advertising