Get Application Commands

Command Set

173

Get Read TX Power (62h)

For deprecated version of this command see Appendix D:

Get Read TX Power (62h)

The Get Read TX Power command returns the current TX power and, optionally, the
minimum and maximum power levels supported by the module (and region setting) for
reading tags, in centi-dBm.

The option field allows you to specify what data you want returned:

The following example gets the full set of power data:

The example response contains the option specified followed by 2 byte fields for each
power value:

current = 0x0BB8 = 3000 centi-dBm = 30.00 dBm
max = 0x0BB8 = 3000 centi-dBm = 30. 00 dBm
min. = 0x01F4 = 500 centi-dBm = 5.00 dBm

Repeat for all available logical antennas, as defined by the settings in

Set Reader Configuration(9Ah)

Option

Data returned

0x00

Returns only the current TX power.

0x01

Returns the current TX power and the maximum
and minimum power levels for this module.