FAULT_MSG_POWER_TOO_LOW - 106h

Cause

A message was received to set the read or write power to a level that is lower than the
current HW supports.

Solution

Check the HW specifications for the supported powers and insure that level is not
exceeded. The M5e supports powers between 5 and 30 dBm. The M5e-Compact units
support power from 10 dBm to 23 dBm.

FAULT_UNIMPLEMENTED_FEATURE - 109h

Cause

Attempting to invoke a command not supported on this firmware or hardware.

Solution

Check the command being invoked against the documentation.

FAULT_INVALID_BAUD_RATE - 10Ah

Cause

When a Set Baud Rate (0x06h) command is issued for a rate that is not specified in the
Baud Rate table, this error message is returned.

Solution

Check the table of specific baud rates and select a baud rate. Send the baud rate in the
hex format. See

Set Baud Rate (06h)

.