ThingMagic M5e-Compact User Manual

Page 110

Advertising
background image

Application Tag Commands

110

Command Set

Read Tag Data Get Data and Metadata Request Fields

A response can contain the following information:

Read Tag Data Get Data and Metadata Response Fields

Field

Value

Description

Option

Bit 4=0
(0x0X)

No Metadata flags are specified and Meta Data will not be
returned. This is the

Get Tag Data

syntax. The lower bits (X) are

specified as defined by

Tag Singulation/Select Functionality

.

Bit 4=1
(0x1X)

Indicates that Metadata flags are to follow and the corresponding
Metadata shall be returned with the tag data. The lower bits (X)
are specified as defined by

Tag Singulation/Select Functional-

ity

.

Metadata Flags
(to specify more
than one OR
the values
together)

0x0000

When no flags are set no meta data will be returned, only the tag
data.

0x0001

When bit 0 is set the Read Count will be returned

0x0002

When bit 1 is set the LQI/RSSI will be returned

0x0004

When bit 2 is set the Antenna ID will be returned

0x0008

When bit 3 is set the Frequency will be returned

0x0010

When bit 4 is set the Timestamp will be returned

0x0020

When bit 5 is set the RFU (T

hingMagic Only

) will be returned

0x0040

When bit 6 is set the Protocol ID will be returned.

0x0080

When bit 7 is set Tag Data information will be returned.
Tag Data is always returned for Read Tag Data, this field cause
an extra 2 bytes, always 0x0000, to be returned for Tag Data
Length

These fields are followed by the

Read Tag Data Fields

then the

Tag Singulation/Select Func-

tionality

(set appropriate bits in the Option field defined above, do not specified an addi-

tional Option field), used the same as defined in the

Get Tag Data

syntax, as necessary.

Field

Length

Value

SOH

1 byte

0xFF

Length

1 byte

Based on data returned

OpCode

1 byte

0x28

Advertising