ThingMagic M5e-Compact User Manual

Page 99

Advertising
background image

Application Tag Commands

Command Set

99

Write Tag EPC Command Fields

The reader sends a Fault Code / ACK response back to the host.

An example of Write Tag EPC command sequence of events and format is shown next:

1.

Starts a timer on the reader.

2.

Wakes the tag.

3.

Programs the tag with the EPC ID

4.

Reads the tag and verifies if the write succeeded.

Note

The verify operation uses the same power level as the write operation. It
does not change to the Read power level.

5.

Sends back an ACK if OK or a fault code for timeout or other faults.

Field

Value

Description

Length

[1 byte]

Number of bytes in the command following the OpCode.

OpCode

0x23

Write Tag EPC

Time Out

[2 bytes]

Command timeout in milliseconds.

Select Options

[1 byte]

The Options value of the

Tag Singulation Fields

Access Password

[4 bytes]

The Access Password of the tags expected to be inventoried for the
embedded command, if they are locked. If the tags are not locked
specify 0x00000000.

Note:

If operating on locked tags, only tags which meet the Select

criteria and matching passwords will get a successful
execution of the embedded command.

Note:

If Select Options=0x00 this field should be omitted.

Tag Singulation Fields

The remaining, fields depending on the value of Select Options.

Tag EPC ID

[M bytes]

Up to 496-bit (

depending on EPC Length parameter setting in

Set Reader Configuration(9Ah)

) tag ID to write to the Tag

FF

00

23

00 00

??

??

SOH

Length

OpCod

e

Status

CRC