Table 7–3, Table 7–4, Show a typical latency that – Altera DDR SDRAM High-Performance Controllers and ALTMEMPHY IP User Manual

Page 126

Advertising
background image

7–4

Chapter 7: Latency

External Memory Interface Handbook Volume 3

June 2011

Altera Corporation

Section I. DDR and DDR2 SDRAM Controllers with ALTMEMPHY IP User Guide

The CAS and write latencies are different between DDR and DDR2 SDRAM
interfaces. To calculate latencies for DDR SDRAM interfaces, use the numbers from
DDR2 SDRAM listed below and replace the CAS and write latency with the DDR
SDRAM values.

Table 7–3. Typical Read Latency in HPC II

(1)

,

(2)

Device

Frequency

(MHz)

Interface

Controller

Latency

(3)

Address and

Command

Latency

CAS

Latency

(4)

Read Data

Latency

Total Read

Latency

(5)

FPGA

I/O

FPGA

I/O

Local

Clock

Cycles

Time

(ns)

Arria GX

233 Half-rate

5

3

1

2

4.5

1

18

154

167

Full-rate

5

2

1

4

5

1

19

114

Arria II GX

233 Half-rate

5

3

1

2.5

5.5

1

18

154

167

Full-rate

5

2

1

4

6

1

20

120

Cyclone III and
Cyclone IV

200 Half-rate

5

3

1

2

4.5

1

18

180

167

Full-rate

5

2

1

4

5

1

19

114

Stratix II and
Stratix II GX

333

Half-rate

5

3

1

2

4.5

1

18

108

267 Half-rate

5

3

1

2

4.5

1

18

135

200 Full-rate

5

2

1

4

5

1

19

95

Stratix III and
Stratix IV

400

Half-rate

5

3

1

2.5

7.125

1.5

20

100

267

Full-rate

4

2

1.5

4

7

1

20

75

Notes to

Table 7–3

:

(1) These are typical latency values using the assumptions listed in the beginning of the section. Your actual latency may be different than shown.

Perform your own simulation for your actual latency.

(2) Numbers shown may have been rounded up to the nearest higher integer.

(3) The controller latency value is from the Altera high-performance controller.

(4) CAS latency is per memory device specification and is programmable in the MegaWizard Plug-In Manager.

(5) Total read latency is the sum of controller, address and command, CAS, and read data latencies.

Table 7–4. Typical Write Latency in HPC II

(1)

,

(2)

(Part 1 of 2)

Device

Frequency

(MHz)

Interface

Controller

Latency

(3)

Address and

Command Latency

Memory

Write

Latency

(4)

Total Write

Latency

(5)

FPGA

I/O

Local

Clock

Cycles

Time

(ns)

Arria GX

233

Half-rate

5

3

1

1.5

12

103

167

Full-rate

5

2

1

3

12

72

Arria II GX

233

Half-rate

5

3

1

2.5

12

103

167

Full-rate

5

2

1

4

12

72

Cyclone III and
Cyclone IV

200

Half-rate

5

3

1

1.5

12

120

167

Full-rate

5

2

1

3

12

72