Daktronics All Sport 4000 Series User Manual

Page 88

Advertising
background image

Event Counter Operation

23-4

23.3.1 RTD Item Numbers

The console sends out data in a Venus 1500 RTD packet as shown below once every
second for code 373, or standard V4600/V7000 RTD for code 374.

Item #

Function

Offset

01

Value x 10,000,000

0

02

Value x 1,000,000

1

03

Value x 100,000

2

04

Value x 10,000

3

05

Value x 1,000

4

06

Value x 100

5

07

Value x 10

6

08

Value x 1

7

23.4

External Input Counter Codes 375 & 376

Code 375 - This code is used for the Venus 1500 Output. Venus 1500 configuration: Baud Rate
19,200, 8 Data Bits, and No Parity.
Code 376 - This code is used for standard RTD Output (V4600/V7000). Venus 4600
configuration: Baud Rate 9,600, 8 Data Bits, and Even Parity.

<

INCREMENT VALUE

!>

This key is used to set the increment value. The increment value can have up to 4
significant digits. This value is the amount that is added to the total value every time an
external switch input 1 is detected.

<

DECREMENT VALUE

!>

This key is used to set the decrement value. The decrement value can have up to 4
significant digits. This value is the amount that is subtracted from the total value each
time an external switch input 2 is detected.

<

TIME INTERVAL

!>

Not used for these codes.

<

START

>

Not used for these codes.

<

STOP

>

Not used for these codes.

<

SET MAIN CLOCK

!>

Not used for these codes.

<

COUNT UP

/

DOWN

!>

Not used for these codes.

Advertising