Incremental signal
If the setting "Incremental signal" is active, the lines (grating periods) are counted and displayed
in the Counter field and in the Position field.
At the counter, for example the grating period of a linear encoder and the interpolation can be
adapted.
The interpolation and the line count of rotary and angle encoders can be selected. The display
mode can be altered as well.
Filter (100 kHz) button = The bandwidth of the input amplifier is damped.
Interfering signal above 100 kHz are suppressed.
Degrees
Counts encoder revolutions in degrees
Radian
measure
360° = 2
= 6.28 (display: 6.28/revolution)
DMS
Degrees / minutes / seconds (see example)