EnDat 2.1 –
Transmission of
position values

EnDat 2.1 can transmit position values with interrupted clock pulse (as in EnDat 2.2) or
continuous clock pulse.

Interrupted clock
The interrupted clock is intended particularly for time-clocked systems such as closed control
loops. At the end of the data word the clock signal is set to HIGH level. After 10 to 30 µs (tm),
the data line falls back to LOW. Then a new data transmission can begin by starting the clock.

The additional information
always begins with

The additional information can contain the following data

Status data
Warning - WRN
Reference mark - RM
Parameter request - Busy
Acknowledgment of
additional information

Additional information 1
Diagnosis (valuation
numbers)
Position value 2
Memory parameters
MRS-code acknowledgment
Test values
Encoder temperature
External temperature
sensors
Sensor data

Additional information 2
Commutation
Acceleration
Limit position signals
Operating status error
sources

Encoder saves

Position value

Subsequent electronics

sends Mode command

Mode command

Cyclic redundancy

check

Position value

Interrupted clock