HEIDENHAIN ATS Software User's Manual

6.3.2 Explanation of the display

Check functions
bar

Level:

Oscilloscope display of the TTL/HTL signals

Position and frequency display

Signal monitoring

Bar graphs of the TTL/HTL signal parameters

Evaluation of the levels

Logic:

TTL measured value recording at very high sampling rate (200 MS/s;
cannot be changed)

Logic analysis of the 0 and 1 levels (no level measurement!)

Measurement of on-to-off ratios TV A / TV B and phase angle

Measurement of REF signal position and width

Measurement of minimum edge separation

Counter:

Test of counting function by counter start/stop with ref. mark.
Function as with 1 Vpp and 11 µApp sinusoidal output signals.
Description of the function: see section “Counter function” on
page 174.

Note

The software indicates if there are calculation problems. If, for example, the frequencies are
too high, or if the displayed signal section is too small to calculate the reference mark, etc.
A yellow Attention symbol is displayed to the right of the Note button.