Dimensioning, Cable lengths – HEIDENHAIN PWM 20 User Manual

Page 217

Advertising
background image

218

HEIDENHAIN ATS Software User's Manual

Recommended input circuit of subsequent electronics

TTL

Dimensioning

Cable lengths

The permissible cable length for transmission of the TTL square-wave signals to the
subsequent electronics depends on the edge separation a. It is 100 m max., or 50 m for the fault
detection signal. The supply voltage at the encoder (see specifications) must be ensured. The
sensor lines can be used to measure the voltage at the encoder and, if required, correct it with
an automatic control system (remote sense voltage supply).

Recommended differential line receivers

DS 26 C 32 AT
AM 26 LS 32 (only if a > 0.1 µs)

MC 3486

SN 75 ALS 193

R

1

4.7 k

R

2

1.8 k

Z

0

120

C

1

220 pF

Advertising