VS-616G5 Programming Manual

Section L: Protection Parameters

L8 Hardware Protection

L8

Hardware Protection
The VS-616-G5 comes equipped with a number of built-in functions designed to protect the inverter
and its components from damage. This section describes the set-up of these functions.

When a Yaskawa dynamic braking resistor is used, protection against overheat is enabled with this func-
tion. The duty cycle of the braking resistor is monitored in software so that it does not exceed 3%.

If the duty cycle exceeds 3%, a DB overheat fault (RH) occurs, and the inverter coasts to stop.

Setting Range:

0 to 100

°

C

Factory Default:

100

°

C

Sets the heatsink temperature level for protection against overheat (OH).

L8-01

Protection Selection for Internal DB Resistor

DB Resistor Prot

B

B

B

B

Setting

Description

0

DB resistor overheat protection is not provided (factory default).

1

DB resistor overheat protection is provided.

L8-02

OH Pre-Alarm Level

OH Pre-Alarm Lvl

A

A

A

A

0

REV Run Regen

Torque Limit (L7-04)

Positive Torque Reference

Negative Torque Reference

FWD Motor Rotation

REV Motor Rotation

REV Run Motor

Torque Limit (L7-02)

FWD Run Regen

Torque Limit (L7-03)

FWD Run Motor

Torque Limit (L7-04)

Figure 56 Torque Limit - 4 Quadrant Operation