VS-616G5 Programming Manual

53

V/f

V/f w/PG Open Loop

Vector

Flux

Vector

ƒ By giving a stop command during torque control, operation changes to speed control automati-

cally, and the motor decelerates to stop. The torque limit during deceleration to stop becomes the
values set in the torque limit parameters (L7-01 to L7-04).

Note:

The control mode actually changes after the speed/torque control selection command changes
and after the reference delay timer (D5-06) elapses. The terminal 13 speed reference/speed
limit and the terminal 16 torque limit/torque reference are stored in the inverter until the time
set to D5-06 elapses.

E

Motor Parameters

E1

V/f Pattern

Setting Range:

155 to 255V (230V class), 310 to 510V (460V class) 445 to 733 (575V class)

<1110>

Factory Default:

230V, 460V, 575V

<1110>

Sets the inverter input voltage in units of 1V.

Select between fan-cooled, blower-cooled and vector/inverter duty motor types with this parameter.

Choose a preset V/f pattern for operation in V/f modes only. It may be necessary to change the V/f pat-
tern when using a high-speed motor, or when special torque adjustment is required in the application.

Set values 0 to E:

preset V/f pattern can be selected

F:

custom V/f pattern can be set (factory default)

Preset V/f patterns are automatically scaled by the input voltage value set in parameter E1-01. Set the
V/f pattern according to the applications described in the table on the following page:

E1-01 Input Voltage

Input Voltage

Q

Q

Q

Q

E1-02 Motor Selection

Motor Selection

Q

Q

Q

Q

Setting

Description

0

Fan-cooled motor characteristics (factory default)

1

Blower-cooled or TENV motor characteristics
This setting allows 120% motor current at and above 5.6 Hz
continuously, and allows 100% motor current at 0 Hz continu-
ously (w/ linear in between).

2

Vector/inverter duty motor

<1110>

This setting allows 120% motor current at all frequencies.

E1-03 V/f Pattern Selection

V/f Selection

Q

Q

Q

Q

Section E: Motor Parameters

E1 V/F Pattern