Section H: Control Circuit Terminals

H2 Digital Outputs

· Overtorque Detection 1 - N.C. (setting: “17”)

Closes during overtorque detection 1 (see section L6, Overtorque Detection, on page 113).

· Overtorque Detection 2 - N.O. (setting: “18”)

Closes during overtorque detection 2 (see section L6, Overtorque Detection, on page 113).

· Overtorque Detection 2 - N.C. (setting: “19”)

Opens during overtorque detection 2 (see section L6, Overtorque Detection, on page 113).

· During Reverse Run (setting: “1A”)

Closes during a reverse run command.

· Baseblock 2 - N.C. (setting: “1B”)

Opens when the inverter output shuts OFF.

· Motor 2 Selection (setting: “1C”)

Closed when motor 2 is selected.

Motor 2 may be selected by using a multi-function digital input.

· Motoring/Regenerating Mode (setting: “1D”)

Closes during regenerative operation (flux vector control only).

· Automatic Restart (setting: “1E”)

Closes during automatic restart operation.

· OL1 Pre-alarm (setting: “1F”)

Closes when the motor-calculated electronic thermal overload value increases to 90% of the internal
fault detection level.

· OH Pre-alarm (setting: “20”)

Closes when the heatsink temperature exceeds the overheat temperature level (L8-02), or when a
multi-function contact input (H1-__ = “B”) closes.

· Current/Torque Limit (setting: “30”)

Closes during torque limit.

· Speed Limit (setting: “31”)

Closes when the speed limit level (D5-03) is reached during torque control (flux vector control).

· Zero-Servo Completion (setting: “33”)

Closes when zero-servo operation is completed.

· During Run 2 (setting: “37”)

Closes when a run command is input (does not close during baseblock, injection braking or initial
excitation).