Section E: Motor Parameters

E4 Motor 2 V/F Pattern / E5 Motor 2 Set-up

The motor 2 parameters are identical to the motor 1 parameters. Refer to E1-03 through E1-10.

E5

Motor 2 Set-up

Sets the motor rated current in units of 0.01A for inverter models 27P5, 47P5 and smaller; 0.1A for
models G5U2011, G5U4011 and larger. The default setting varies depending on the inverter model set-
ting (O2-04).

Setting range:

0.00 to 20.00Hz

Sets the motor rated slip frequency in units of 0.01Hz. The default setting varies depending on the
inverter model setting (O2-04). Use the following equation to calculate the motor rated slip frequency:

Sets the motor no-load current in units of 0.01A for inverter models 27P5, 47P5 and smaller; 0.1A for
models G5U2011, G5U4011 and larger. The default setting varies depending on the inverter model set-
ting (O2-04).

Setting Range:

2 to 48 poles

Factory Default:

4 poles

Sets the number of motor poles for motor 2.

E4-01 Motor 2 Maximum Frequency

Max Frequency

A

A

A

A

E4-02 Motor 2 Maximum Voltage

Max Voltage

A

A

A

A

E4-03 Motor 2 Base Frequency

Base Frequency

A

A

A

A

E4-04 Motor 2 Middle Output Frequency A

Mid Frequency A

A

A

A

E4-05 Motor 2 Middle Output Voltage A

Mid Voltage A

A

A

A

E4-06 Motor 2 Minimum Output Frequency

Min Frequency

A

A

A

A

E4-07 Motor 2 Minimum Output Voltage

Min Voltage

A

A

AA

E5-01 Motor 2 Rated Current

Motor Rated FLA

A

A

A

A

E5-02 Motor 2 Rated Slip Frequency

Motor Rated Slip

A

A

A

A

E5-03 Motor 2 No-Load Current

No-Load Current

A

A

A

A

E5-04 Motor 2 Number of Motor Poles

Number of Poles

A

A

where:

f

s

f

N P

(

)

120

-----------------

=

f : slip frequency (Hz)

f : rated frequency (Hz)
N : rated motor speed (rpm)
P : number of motor poles