Motorized Faders

VM200 User’s Guide

153

If you have set the Program Change/Tx parameter to On, the VM200
transmits a Program Change message each time you recall a scene.
(The Program Change/Tx parameter appears on the Setup: MIDI

1:MIDI TX&RX

function page. See “Program Change Messages” on

page 177 for more information.) Using this capability, you can recall
programs on other MIDI equipment, such as a tone program on a syn-
thesizer. You can record transmission of Program Change messages
from the VM200 to a MIDI sequencer to later automate mix scene
changes. Refer to the “Using Program Change Messages to Recall
Scenes” on page 180 for mor
e information.

Motorized Faders

In order for the faders to move to their new positions automatically
when you change scenes, the Motor parameter must be turned on.
The Motor parameter appears on the

SETUP: SYSTEM 1:CLOCK/MON

func-

tion page.

Follow the steps below to turn the motorized faders on or off.

1.

Press the

[SYSTEM]

key once to display the

1: CLOCK/MON

func-

tion page.

2.

Rotate the EQ/LO Q rotary control to turn the Motor parame-
ter on or off.

The default setting is “OFF.”

Warning:

Do not force the automated faders or you may damage the

VM200.

Note:

If the Motor parameter is turned on, the fader will move suddenly

and automatically when a new scene is recalled or the Fader Mode is
changed.

turning motorized faders on and off