Using control change messages, Solo – Fostex VM200 User Manual

Page 184

Advertising
background image

VM200 & MIDI

184

VM200 User’s Guide

Using Control Change Messages

When the VM200 receives a MIDI Control Change message, it can
adjust a mix parameter specified by the Control Change Assign Table.
(For more information, see page 211.)

Similarly, when a mix parameter is adjusted on the VM200, the
VM200 can transmit a Control Change message to control another
VM200.

Alternatively, you can record Control Change messages to a MIDI
sequencer and use them later to automate parameter control.

You can assign up to 114 mix parameters to Control Changes 0
through 95 and 102 through 119. (Due to the MIDI standard, Control
Changes 96 through 101 are unavailable.)

The VM200 “Control Change To Control Parameters Assignment
Tables” on page 211 lists initial assignments. Y
ou can edit these
assignments using the

4:CTL TABLE1

function page.

Follow these steps to set up the VM200 to receive and transmit MIDI
Control Change messages:

1.

Press the

[MIDI]

key.

The VM200 displays the

1:MIDI TX&RX

function page.

2.

Set the VM200 and the external MIDI device to the same
MIDI channel.

The external MIDI device that receives MIDI messages from the
VM200 should be set to the MIDI Channel specified by the TX CH
parameter.

The RX CH parameter of the VM200 should be set to the same
MIDI Channel as the device transmitting MIDI messages.

3.

Set the TX CH and/or RX CH parameters to ON.

Use the EQ/LO and EQ/LO-MID GAIN rotary controls. Refer to
the illustration below.

Advertising