Editing the Control Change Assign Table

VM200 UserÕs Guide

185

Editing the Control Change Assign Table

The VM200 features two Control Change Assign Tables.

The first is the User Table, which appears on the

4:CTL TABLE1

function

page. You can edit the assignments in this table.

The second table is the Preset Table, which appears on the

5:CTL TABLE2

function page. You can view the assignments in the Preset table, but
not edit them.

Follow the steps below to assign a control parameter to a Control
Change number.

1.

Press the

[MIDI]

key four times.

The VM200 displays the

4:CTL TABLE1

function page.

The following page appears on the display.

2.

Select a Control Change number.

Rotate the EQ/LO GAIN rotary control to select a Control Change
number from 0 through 95 or 102 through 119. (Numbers 096
through 101 are unavailable).

3.

Select the section of the VM200 you wish to control with the
Control Change number.

Rotate the EQ/LO-MID GAIN rotary control to select the section
you wish to control with the selected Control Change number.

Options include NON, CHANNEL, MASTER, EFFECT, and SCENE
ST.

4.

Select the sub-section of the VM200 you wish to control.

Rotate the EQ/HI-MID GAIN rotary control to select a sub-section.

Options include CH1–20, ST BUSS, REC BUSS, AUX1–4, EFF1–2,
MODE, PST/PRE, and AUX PAIR. The available options vary
depending on your previous selections.

5.

Select a parameter item you wish to control with the selected
Control Change number.

Rotate the EQ/HI

[GAIN]

rotary control to select a parameter item.

The available options vary depending on your previous selections.

For more information, refer to the “Control Change To Control
Parameters Assignment Tables” on page 211.