3 baudrate, 4 exec-timeout – Fortinet MR1 User Manual

Page 133

Advertising
background image

133

Syntax

line console

Default Setting

None

Command Mode

Global Config

5.3.2.3 baudrate

This command specifies the communication rate of the terminal interface. The supported
rates are 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200.

Syntax

baudrate {1200 | 2400 | 4800 | 9600 | 19200 | 38400 | 57600 | 115200}

no baudrate

no - This command sets the communication rate of the terminal interface to 115200.

Default Setting

115200

Command Mode

Line Config

5.3.2.4 exec-timeout

This command specifies the maximum connect time (in minutes) without console activity. A
value of 0 indicates that a console can be connected indefinitely. The time range is 0 to 160.

Syntax

exec-timeout <0-160>