iRMC S2/S3

131

Providing remote storage via a Remote Storage server

Configuring the Remote Storage server

I

Configuration is only possible if the Remote Storage server is in the “idle”
state, i.e. it is not being executed.

In the graphical user interface, you specify the image file made available as
remote storage together with other parameters:

ISO Image Path and Filename:

Ê

Enter the path and name of the image file directly in the field.

or:

Ê

Click the

Browse...

button and then navigate to and select the required

image file in the

Choose a file

dialog which now opens and then

confirm.

I

If the Remote Storage server is to run as a service (see the

Run

as Service

option on

page 132

) and the image file is located on a

computer in the network, you must specify the path of the image
file in UNC notation. You must also ensure that the account
entered under

Log On As User

(see

page 132

) is valid and has

access permissions on the share on which the image file is
located.

Force Using Port

If you have configured a port number other than the default port number
(5901) for the iRMC S2/S3’s remote storage port (see

page 248

), then

you must activate this option and enter the configured port number in the
associated field.

Force Using IP Address

If the host on which the Remote Storage server is executed possesses
more than one LAN connection:
You can specify the IP address of the LAN connection that is to be used
for the Remote Storage server if this is executed as a service.
By default, the Remote Storage server uses the first detected LAN
connection.