FUJITSU INTEGRATED REMOTE MANAGEMENT CONTROLLER IRMC S2/S3 User Manual

Page 219

Advertising
background image

iRMC S2/S3

219

Sensors - Check status of the sensors

Power Supply Redundancy Configuration

I

This functionality is not available with all servers.

The

Power Supply Redundancy Configuration

group allows you to set the

redundancy mode for the managed server. It depends on the servers
capabilities which options are actually available.

PSU Redundancy 1 + 1 Spare PSU

System operation is guaranteed for 1 PSU fail in the case of 2 PSUs in
total.

PSU Redundancy 2+ 1 Spare PSU

System operation is guaranteed for 1 PSU fail in the case of 3 PSUs in
total.

PSU Redundancy 3+ 1 Spare PSU

System operation is guaranteed for 1 PSU fail in the case of 4 PSUs in
total.

AC Redundancy 2 + 2 (2 AC sources)

2 of the 4 PSUs are each connected to a separate AC source. This
ensures that the system can continue operation even if a power line or a
single PSU fails.

AC Redundancy 1 + 1 (2 AC sources)

Each PSU (of 2 PSUs in total) is connected to a separate AC source. This
ensures that the system can continue operation even if a power line or a
single PSU fails.

Advertising