IPMI OEM Commands supported by the iRMC S2/S3

01 20 - Set Next Power On Time

This command switches on a system at the given time independent of the stored
On/Off times in the Configuration Space.

I

The command takes effect only once.

You cancel a “Power On” time previously set with a 01 20 command by
specifying the “Power On” time “0” in a subsequent 01 20 command.

Time (LSB first)

Time (UNIX-specific format) when the system switches on again. Time is
NOT stored in non-volatile memory. Resolution is 1 minute. After the
system has switched on, Time is set to 0 internally.
If Time == 0, the system is not switched on.

Request Data

-

B8

NetFnlLUN: OEM/Group

-

01

Cmd : Command Group Communication

1:3

80 28 00

IANA-Enterprise-Number FTS, LS byte first

4

20

Command Specifier

5

00

Object ID

6:7

00 00 Value ID

8

04

Data Length

9:12

Time (LSB first) (see below)

Response Data

-

BC

-

01

1

Completion Code

2:4

80 28 00

IANA-Enterprise-Number FTS, LS byte first