Sensors - Check status of the sensors

Ê

Define the behavior in the event of a fault using the list at the bottom of the
work area:

Choose

continue

if the server is not to be shut down if the selected fans

fail.

Choose

shutdown-and-power-off

if the server is to be shut down and

powered down if the selected fans fail. If you choose this option, you must
also specify the time in seconds between failure of the fan and shutdown
of the server (Shutdown Delay) in the field to the right of the list.

I

In the case of redundant fans, shutdown is only initiated if more
than one fan is faulty and

shutdown-and-power-off

is also set for

these fans.

Ê

Click

Apply to the selected Fans

to activate your settings for the selected fans.