Configuring text console redirection via LAN

3.2.3

Using console redirection while the operating
system is running

Depending on the operating system used on the managed server, you can
continue to use console redirection after the BIOS POST phase.

DOS

The BIOS setting for console redirection mode must be set as follows (see
section

"Settings in the Console Redirection menu" on page 50

):

BIOS setup utility:

Mode: Enhanced

TrustedCore setup utility:

Continue C.R. after POST: On

Windows Server 2003 / 2008

I

If activated during Windows installation, console redirection is thereby
automatically configured.

If console redirection is activated after Windows installation has
completed, you must configure console redirection manually.

Windows Server 2003 / 2008 handles console redirection automatically after the
POST phase. No further settings are necessary. While the operating system is
booting, the Windows Server 2003 SAC console is transferred:

Figure 15: Windows Server 2003 SAC console