FUJITSU INTEGRATED REMOTE MANAGEMENT CONTROLLER IRMC S2/S3 User Manual

Page 51

Advertising
background image

iRMC S2/S3

51

Configuring text console redirection via LAN

Mode

This setting affects the behavior of console redirection while the
operating system is running (after the POST phase has completed) -
see

section "Using console redirection while the operating system is

running" on page 55

:

Standard

Console redirection is terminated after the BIOS POST phase.

Enhanced

Console redirection continues to be available after the BIOS
POST phase.

Ê

Make the following settings in the TrustedCore setup utility:

Figure 12: Console Redirection menu (as it appears in the TrustedCore setup utility)

Com Port Address

Set the value to

On-board COM A

.

Baud Rate

Specify the baud rate.

Console Type

Leave this setting unchanged. (The setting depends on the terminal
type used.)