FUJITSU INTEGRATED REMOTE MANAGEMENT CONTROLLER IRMC S2/S3 User Manual

Page 221

Advertising
background image

iRMC S2/S3

221

Sensors - Check status of the sensors

Entries with Designation "iRMC", "Agent", "BIOS", or "VIOM"

Entries with the

Designation

"iRMC", "Agent", "BIOS", or "VIOM" indicate that the

iRMC S2/S3, the agent, the BIOS, or VIOM has detected an error. It does not
mean that the iRMC S2/S3, the agent, the BIOS, or VIOM itself is defective.

Entries with Designation "HDD" and "HDD<n>, agentless HDD monitoring
("out-of-band" HDD monitoring)

Entries with the

Designation

"HDD" or "HDD<n>" (with n = 1, 2, ...) indicate the

statuses of Hard Disk Drives (HDD):

The entry with

Designation

"HDD" indicates the overall HDD status of the

server by summarizing the statuses of the individual HDDs.

The overall HDD status of the server is read and reported to the iRMC S2/S3
by the ServerView agents and the ServerView RAID Manager.

An entry with

Designation

"HDD<n>" (where n = 1, 2, ...) indicates the status

of an individual HDD.

I

Please note:

This feature is only supported by the iRMC S3.

This feature only supported if the managed PRIMERGY server
supports the "agentless HDD monitoring" function (also known as
"out-of-band HDD monitoring").

If these requirements are met, the HDD<n> status of each individual
HDD is reported directly to the iRMC S3, i.e. without using the
ServerView agents.

Figure 123: Status display for individual HDDs

Advertising