Using the remote manager (serial) interface, 3 using the remote manager (serial) interface – FUJITSU INTEGRATED REMOTE MANAGEMENT CONTROLLER IRMC S2/S3 User Manual

Page 62

Advertising
background image

62

iRMC

S2/S3

Configuring and using the serial interface of the iRMC S2/S3

Flow Control

None

Exiting the UEFI setup utility

Ê

Save your settings and exit the UEFI setup utility.

Ê

Continue with

section "Testing the LAN interface" on page 47

.

3.3.3

Using the Remote Manager (Serial) interface

If you connect a computer over a null modem cable and start a terminal program
(VT100+) on this computer, you can access the Remote Manager (Serial)
terminal program. The Remote Manager (Serial) interface is identical to the
Remote Manager interface (see

chapter "iRMC S2/S3 via Telnet/SSH (Remote

Manager)" on page 321

).

Prerequisites

On the managed server:

The

Serial Multiplexer

BIOS setting must be configured on the

iRMC

(see

section "Configuring the serial interface of the iRMC S2" on page 58

).

Terminal program (VT100+):

Configure the following port settings for the terminal program:

Bits per second

Set the value to

9600

.

Data bits

Set the value to

8

.

Parity

Set the value to

None

.

Stop bits

Set the value to

1

.

Flow Control

Set the value to

None

.

Advertising