FUJITSU INTEGRATED REMOTE MANAGEMENT CONTROLLER IRMC S2/S3 User Manual

Page 205

Advertising
background image

iRMC S2/S3

205

Power Consumption

Warning Threshold

Threshold as a percentage of the maximum power consumption
specified under

Power Limit

. When the threshold is reached, the action

defined under

Action Reaching Power Limit

is performed.

Power Limit Grace Period

Period (in minutes) for which the system waits after the threshold has
been reached until the action is performed.

Action Reaching Power Limit

Action to be performed after the threshold has been reached and the
grace period has expired.

Continue

No action is performed.

Graceful Power Off (Shutdown)

Shut down the system "gracefully" and power it down.

I

This option is only supported if ServerView agents are
installed and signed onto the iRMC S2/S3 as “Connected”.

Immediate Power Off

The server is immediately powered down irrespective of the status
of the operating system.

Enable Dynamic Power Control

The power limit is controlled dynamically. If this option is enabled, the
iRMC S2/S3 controls the power consumption of the server system by
reducing the CPU’s power consumption as soon as the

Warning Threshold

is reached.