Scheduled power – FUJITSU INTEGRATED REMOTE MANAGEMENT CONTROLLER IRMC S2/S3 User Manual

Page 202

Advertising
background image

202

iRMC

S2/S3

Power Consumption

Enable Power Monitoring

If you enable this option, power consumption is monitored over time.

I

Power monitoring is enabled by default as of Version 3.32 of the
firmware.

I

This setting only takes effect on PRIMERGY servers that support
power monitoring.

Ê

Click

Apply

to activate your settings.

Scheduled Power Consumption Configuration

The

Scheduled Power Consumption Configuration

group allows you to specify in

detail the schedules and modes (operating-system-controlled, best
performance, lowest power consumption) that the iRMC S2/S3 uses to control
power consumption on the managed server.

I

The

Scheduled Power Consumption Configuration

group only appears if you

have enabled the power control mode

scheduled

in the

Power Consumption

Options

group.

I

Configuration for scheduled power control mode assumes that the

Enhanced Speed Step

option has been enabled in the BIOS setup. If this is

not the case, a message to this effect is displayed.

If this message appears even though “Enhanced Speed Step” is
enabled, this may be because:

The CPU (e.g. low-power CPU) of the server does not support
scheduled power control.

The system is currently in the BIOS POST phase.