410

iRMC

S2/S3

IPMI OEM Commands supported by the iRMC S2/S3

F5 DF - Reset Nonvolatile Cfg Variables to Default

This command forces all non-volatile IPMI settings to be set to default values.

F5 E0 - Reset ConfigSpace variables to default

This command forces all Configuration Space variables to be set to default
values.

Request Data

-

B8

NetFnlLUN: OEM/Group

-

F5

Cmd : Command Group BMC

1:3

80 28 00

IANA-Enterprise-Number FTS, LS byte first

4

DF

Command Specifier

5:8

43 4C 52 AA = ’CLR’0xaa: Security Code

Response Data

-

BC

-

F5

1

Completion Code

2:4

80 28 00

IANA-Enterprise-Number FTS, LS byte first

Request Data

-

B8

NetFnlLUN: OEM/Group

-

F5

Cmd : Command Group BMC

1:3

80 28 00

IANA-Enterprise-Number FTS, LS byte first

4

E0

Command Specifier

5:8

43 4C 52 AA = ’CLR’0xaa: Security Code

Response Data

-

BC

-

F5

1

Completion Code

2:4

80 28 00

IANA-Enterprise-Number FTS, LS byte first

Advertising