Updating firmware images

10.3

Updating firmware images

Since the iRMC S2/S3 firmware executes in the SRAM memory of the
iRMC S2/S3, it is possible to update both active and inactive firmware images
online, i.e. with the server operating system running.

The following methods are available for updating the firmware images:

–

over the iRMC S2/S3 web interface

–

using the ServerView Update Manager

–

using ServerView Update Manager Express or ASP

–

Update using the operating system flash tools.

Downgrading the firmware to the previous version

Besides the possibility of performing a firmware update, you can also
downgrade the firmware to the previous version.

The simplest way to downgrade the firmware is to store the previous-version
firmware image as the inactive firmware image in the EEPROM of the
iRMC S2/S3. In this case, you only have to set the firmware selector to this
previous-version image (see

page 182

) and subsequently restart the

iRMC S2/S3 to activate the firmware.

I

You can also downgrade the firmware by applying the methods described
in the following sections. In these cases, you perform a firmware update
based on the firmware of the previous version. Special requirements to
perform the downgrade are pointed out separately in the following
sections.

10.3.1 Update via the iRMC S2/S3 web interface

The

iRMC S2/S3 Firmware Update

page allows you to update the firmware of the

iRMC S2/S3 by providing the firmware image either locally on the remote
workstation or on a TFTP server (see

section "iRMC S2/S3 Firmware Update"

on page 181

).