FUJITSU INTEGRATED REMOTE MANAGEMENT CONTROLLER IRMC S2/S3 User Manual

Page 415

Advertising
background image

iRMC S2/S3

415

Configuring the iRMC S2/S3 via SCCI and scripted configuration

Parameters of SCCI provider-specific commands

The following SCCI-provider-specific commands are available:

Operation Code (

OC

)

Hex value or string specifying the command / operation code.

I

The iRMC S2/S3 only supports a limited set of SCCI commands.
For a list of supported commands see

table "SCCI commands

supported by the iRMC S2/S3" on page 420

Operation Code Extension (

OE

)

Hex value for extended operation code. Default:

OE=0

For ConfigSpace Read-/Write operations, this value defines the
ConfigSpace ID.

Object Index (

OI

)

Hex value selecting an instance of an object. Default:OI=0"

Operation Code Type (

Type

)

For configuration settings, the values

GET

(read operation) and

SET

(write

operation) are supported. Default: Type=GET

I

SET

operations require data. For specifying the appropriate data

type, use the

Data (DATA)

parameter described below.

Cabinet Identifier (

CA

)

Allows you to select an extension cabinet and use its cabinet ID number.

I

Do not use this parameter to request for the system cabinet!

Data (

DATA

)

If a

SET

parameter (write operation) is specified: Data type (

Type

parameter), and, in some cases, data length (

LEN

parameter) are

required.

Currently, the following data types are supported:

xsd::integer

Integer value

Example

<DATA Type="xsd::integer">1234</DATA>