iRMC

S2/S3

Server Management Information - Configuring the server settings

ASR&R Options - Configure ASR&R settings

The

ASR&R Options

group allows you to configure the ASR&R (automatic server

reconfiguration and restart) settings for the server.

I

The settings made on the

ASR&R Options

group become active the next

time the managed server is started.

Figure 133: Server Management Information page, ASR&R Options

Retry counter Max (0 - 7)

Maximum number of restart attempts that should be permitted for the
server after a critical error (up to 7).

Retry counter (0 - Max)

Number of restart attempts that a server should attempt after a critical
error (maximum value is the value set under

Retry counter Max

).

BIOS recovery flash bit

Enables/disables the BIOS recovery flash bit:

Enabled

The next time the system is booted, the BIOS is automatically
flashed.

Disabled

The next time the system is booted, the BIOS is not automatically
flashed.

I

The

Enabled

setting is of value if the operating system no longer

boots after the firmware has been updated. A BIOS recovery flash
is then performed automatically the next time the system is booted
from the DOS floppy (or a DOS floppy image).

After a BIOS recovery flash has been performed successfully,
reset the BIOS Recovery Flash bit to

disabled

.