12.1.2.2 SCCI-compliant Power On/Off commands

01 15 - Get Power On Source

This command returns the reason for the most recent Power On. The possible
reasons are listed below.

Request Data

-

B8

NetFnlLUN: OEM/Group

-

01

Cmd : Command Group Communication

1:3

80 28 00

IANA-Enterprise-Number FTS, LS byte first

4

15

Command Specifier

Response Data

-

BC

-

01

1

Completion Code

2:4

80 28 00

IANA-Enterprise-Number FTS, LS byte first

3

01

Data Length

4

Power on Source: Cause of last power on

Power on

Source

Description

0x00

Software or command

0x01

Power switch (on the front panel or keyboard)

0x02

Automatic restart after power failure

0x03

Clock or timer (hardware RTC or software timer)

0x04

Automatic restart after fan failure shutdown

0x05

Automatic restart after critical temperature shutdown

0x08

Reboot after watchdog timeout

0x09

Remote on (modem RI line, SCSI termination power, LAN, chip card
reader...)

0x0C

Reboot after a CPU error

0x15

Reboot by hardware reset

0x16

Reboot after warm start

0x1A

Powered on by a PCI Bus Power Management Event

0x1D

Powered on by remote control via remote manager

0x1E

Reboot/reset by remote control via remote manager