12.2.1.3 Restrictions

All commands specified in the

.pre

file are normally executed sequentially. The

following are exemptions from this rule:

–

To prevent broken network connectivity, commands for IPv4 and VLAN
network configuration are executed at the end of a command sequence.

–

Currently, IPv6 configuration is limited to the configuration of the non-volatile
IPv6 configuration parameters.

As a workaround, you can proceed as follows:

1. Arrange your script as follows:

a) At the beginning of the script: Disable IPv6.

b) Configure IPv6 parameters.

c) At the end of the script: Enable IPv6

2. Submit the script from an IPv4 address.

–

The SSL certificate and the related matching private key are executed at the
end of a command sequence. Both components must be present in the
same

.pre

file and are checked for matching each other.

–

If a power management operation for the managed server or a reboot of the
iRMC S2/S3 is required or desired:

It is recommended (but not required) to run these commands in separate
command files. You can achieve this e.g. by splitting the configuration and
power management operations into separate tasks.

–

Optional time delays between the execution of consecutive commands must
implemented outside the script.

For example, you can achieve this as follows:

1. Devide the script appropriately into separate scripts.

2. Use the functional range of the client to insert time delays between

sending the individual files.