iRMC

S2/S3

Console Redirection - Redirecting the console

Console Redirection Port

Two serial ports are available:

Serial 1

,

Serial 2

.

I

If console redirection is to be performed via LAN, Serial 1 must be
set.

If

Serial 2

is selected, only the connection over the null modem

cable works.

Serial Port Baud Rate

The following baud rates can be set: 1200, 2400, 4800, 9600, 19200,
38400, 57600, 115200.

Serial Port Flow Control

The following settings are possible:

None

Flow control is disabled.

XON/XOFF (Software)

Flow control is handled by the software.

CTS/RTS (Hardware)

Flow control is handled by the hardware.

Terminal Emulation

The following terminal emulations are available:

VT100 7Bit, VT100 8Bit

,

PC-ANSI 7Bit

,

PC-ANSI 8 Bit, VT100+

,

VT-UTF8

Serial 1 Multiplexer

Check the consistency of the multiplexer settings:

Serial: System

LAN: iRMC S2/S3

Ê

Click

Apply

to activate your settings.