FUJITSU INTEGRATED REMOTE MANAGEMENT CONTROLLER IRMC S2/S3 User Manual

Page 54

Advertising
background image

54

iRMC

S2/S3

Configuring text console redirection via LAN

Ê

Call the

Console Redirection

menu:

Figure 14: Console Redirection menu

Ê

Make the following settings in the

Console Redirection

menu:

Console Redirection

Set the value to

Serial 1

. In this case, the terminal uses the first serial

interface.

Baud Rate

Specify the baud rate.

Protocol

Leave this setting unchanged. (The setting depends on the terminal
type used.)

Flow Control

The setting depends on the terminal type used. The settings must be
the same on both terminal and managed server.

Exiting the UEFI setup utility

Ê

Save your settings and exit the UEFI setup utility.

Ê

Continue with

section "Testing the LAN interface" on page 47

.