IPMI OEM Commands supported by the iRMC S2/S3

01 1C - Set Power Off Inhibit

This command sets the

Power Off Inhibit

flag, which temporarily suppresses any

unfounded attempt to power down the server.

If the

Power Off Inhibit

flag is set, the firmware saves the cause of any attempt to

perform a “Power Off”, “Power Cycle” or restart of the server, but does not
perform the action. The cause of the most recent attempt to perform a “Power
Off”, “Power Cycle” or restart of the server is always saved at any given time.
The stored action is only performed when the

Power Off Inhibit

flag is reset.

The

Power Off Inhibit

flag is automatically reset after a power failure or when the

reset button is pressed.

The effect of the

Power Off Inhibit

flag is the same as that of the Dump flag used

when creating a main memory dump. In this case, the initiator must set the flag
before making the dump and reset it when the dump is complete.

Request Data

-

B8

NetFn|LUN: OEM/Group

-

01

Cmd : Command Group Communication

1:3

80 28 00

IANA-Enterprise-Number FTS, LS Byte first

4

1C

Command Specifier

5

00

Object ID

6:7

00 00 Value ID

8

01

Data Length

9

Power Off Inhibit Flag: 0 no Inhibit, 1 Inhibit