FUJITSU INTEGRATED REMOTE MANAGEMENT CONTROLLER IRMC S2/S3 User Manual

Page 407

Advertising
background image

iRMC S2/S3

407

IPMI OEM Commands supported by the iRMC S2/S3

F5 45 - Get SEL Entry Text

This command translates a given System Event Log SEL entry into ASCII text.

Request Data

-

B8

NetFnlLUN: OEM/Group

-

F5

Cmd : Command Group iRMC

1:3

80 28 00

IANA-Enterprise-Number FTS, LS Byte first

4

45

Command Specifier

5:6

Record ID of SDR, LS Byte first

Response Data

-

BC

-

F5

1

Completion Code

2:4

80 28 00

IANA-Enterprise-Number FTS, LS Byte first

5:6

Next Record ID

7:8

Actual Record ID

9

Record type

10:13

Timestamp

14

Severity:

Bit 7:

0 = No CSS component

1 = CSS component

Bit 6-4:

000 = INFORMATIONAL

001 = MINOR
010 = MAJOR
011 = CRITICAL
1xx = Unknown’

Bit 3-0:

reserved, read as 0000

15

Data length

16:35

Converted SEL data

Advertising