2 signal measurement modes, 1 measurement input width (mode 4), Signal measurement modes -14 – Motorola DSP56301 User Manual

Page 276: Measurement input width (mode 4) -14, 2 signal measurement modes

Advertising
background image

Operating Modes

9

-14

DSP56301 User’s Manual

9.3.2

Signal Measurement Modes

The following signal measurement and pulse width modulation modes are provided:

n

Measurement input width (Mode 4)

n

Measurement input period (Mode 5)

n

Measurement capture (Mode 6)

n

Pulse width modulation (PWM) mode (Mode 7)

The external signal synchronizes with the internal clock that increments the counter. This
synchronization process can cause the number of clocks measured for the selected signal
value to vary from the actual signal value by plus or minus one counter clock cycle.

9.3.2.1 Measurement Input Width (Mode 4)

In Mode 4, the timer counts the number of clocks that occur between opposite edges of an
input signal. After the first appropriate transition (as determined by the TCSR[INV] bit)
occurs on the

TIO

input signal, the counter is loaded with the TLR value. If TCSR[INV] is set,

the timer starts on the first high-to-low (1 to 0) signal transition on the

TIO

signal. If the INV

bit is cleared, the timer starts on the first low-to-high (that is, 0 to 1) transition on the

TIO

signal. When the first transition opposite in polarity to the INV bit setting occurs on the

TIO

signal, the counter stops. TCSR[TCF] is set and a compare interrupt is generated if the
TCSR[TCIE] bit is set. The value of the counter (which measures the width of the TIO pulse)
is loaded into the TCR, which can be read to determine the external signal pulse width. If the
TCSR[TRM] bit is set, the counter is loaded with the TLR value on the first timer clock
received following the next valid transition on the

TIO

input signal, and the count resumes. If

TCSR[TRM] is cleared, the counter continues to increment on each timer clock. This process
repeats until the timer is disabled.

Bit Settings

Mode Characteristics

TC3

TC2

TC1

TC0

Mode

Name

Function

TIO

Clock

0

1

0

0

4

Input width

Measurement

Input

Internal