Figure 73. Critical Dimensions for Component Placement

Intel®
82562ET /

82562EM

B

A

ICH2

EEPROM

Magnetics

Module

Line

RJ45

crit_dim_comp_plac

Distance Priority Guideline

A 1

<1

inch

B 2

<1

inch

2.22.4.4.1. Distance from Magnetics Module to RJ45

Distance ‘A,’ in the previous figure, should be given the highest priority during board layout. The
separation between the magnetics module and the RJ45 connector should be kept to less than 1 inch. The
following trace characteristics are important and should be observed:

Differential impedance: The differential impedance should be 100

. The single-ended trace

impedance is approximately 50

. However, the differential impedance also can be affected by the

spacing between traces.

Trace symmetry: Differential pairs (e.g., TDP and TDN) should be routed with consistent separation
and with exactly the same lengths and physical dimensions (e.g., width).

Caution: Asymmetric and unequal-length traces in the differential pairs contribute to common-mode noise. This

can degrade the receive circuit’s performance and contribute to radiated emissions from the transmit
circuit. If the Intel

82562ET component must be placed farther than a couple of inches from the RJ45

connector, distance B can be sacrificed. It should be a priority to minimize the total distance between the
Intel

82562ET component and RJ-45.

Note: The measured trace impedance for layout designs targeting 100

often yields a lower actual impedance.

OEMs should verify the actual trace impedance and adjust their layout accordingly. If the actual

impedance is consistently low, a target of 105

–110

should compensate for second-order effects.