2.7.5.

Direct RDRAM* Clock Routing

Refer to Chapter 4 Clocking for the Intel 820E chipset platform’s Direct RDRAM clock routing
guidelines.

2.7.6.

Direct RDRAM* Design Checklist

Use the following checklist as a final check to ensure that the motherboard incorporates solid design
practices. This list is only a reference. For correct operation, all of the design guidelines within this
document must be followed.

Table 9. Signal List

RSL Signals

High-Speed

CMOS Signals

Serial

CMOS Signal

Clocks

DQA[8:0]

DQB[8:0]

RQ[7:0]

CMD

SCK

SIO

CTM

CTM#

CFM

CFM#

Ground isolation well grounded.

Via to ground every 0.5 inch around edge of isolation island

Via to ground every 0.5 inch between RIMMs

Via to ground every 0.5 inch between signals (from MCH to first RIMM)

Via between every signal within 100 mils of the MCH edge and the connector edge

No unconnected ground floods

All ground isolation at least 10 mils wide.

Ground isolation fills between serpentines

Ground isolation not broken by C-TABs.

Ground isolation connects to the ground pins in the middle of the RIMM connectors.

Ground isolation vias connect on all 4 layers and should not have thermal reliefs.

Ground pins in RIMM connector connect on all 4 layers.

V

TERM

layout yields low noise.

Solid V

TERM

island is on top layer. Do not split this plane.

Ground island (for ground side of V

TERM

caps) is on top.

Termination resistors connect directly to the V

TERM

island on the top layer (without vias).

Decoupling V

TERM

is critical!

Decoupling capacitors connect directly to top-layer V

TERM

island and top-layer ground island.

(See the layout example.)

Use at least 2 vias per decoupling capacitor in the top-layer ground island.

Use 2

×

100

µ

F tantalum capacitors to decouple V

TERM

. (Aluminum/electrolytic capacitors are

too slow!)

High-frequency decoupling capacitors must be spread out across the termination island so that
all termination resistors are near high-frequency capacitors.

100

µ

F tantalum capacitors should be at each end of the V

TERM

island.

100

µ

F tantalum capacitors must be connected directly to V

TERM

island.

100

µ

F tantalum capacitors must have at least 2 vias/cap to ground.

V

TERM

island should be 50–75 mils wide.

V

TERM

island should not be broken.