B&K Precision 2552-2559 - Manual User Manual

Page 147

Advertising
background image

147

details on the number of data points that can be saved to a CSV file can be

found in the storage chapter of this manual. The number of data points

that can be captured via USB device interface using the EasyScope

software is specified in the EasyScope manual.

Trigger System

Trigger

Types

Edge, Pulse Width, Video, Slope, Alternate

*Trigger

Source

CH1, CH2, CH3, CH4, EXT, EXT/5, AC Line

Trigger

Modes

Auto, Normal, Single

Trigger

Coupling

AC, DC, LF reject, HF reject

*Trigger

Level Range

CH1,CH2, CH3, CH4: ± 6 divisions from center of

screen

EXT: ± 1.2 V

EXT/5: ± 6 V

Trigger Level

Accuracy

(typical)

applicable for

the signal of

rising and

falling time ≥

20ns

Internal: ± (0.2 div × V/div) ( within ± 4 divisions

from center of screen)

EXT: ± (6% of setting + 40 mV)

EXT/5: ± (6% of setting + 200 mV)

Trigger

Sensitivity

For fixed gain ranges

1 Divisions: DC - 10 MHz

1.5 Divisions: 10 MHz – Ma.x BW

EXT: 200 mVpp DC-10 MHz,

300 mVpp 10 MHz – Ma.x BW

EXT/5: 1 Vpp DC-10 MHz,

1.5 Vpp 10 MHz – Max. BW

Pulse Width

Trigger

Trigger Modes: (>, <, =) positive Pulse Width, (>, <, =)

Negative Pulse Width

Pulse width range: 20 ns – 10 s

Video

Trigger

Support signal formats: PAL/SECAM, NTSC

Trigger condition : odd field, even field, all lines, line

Num