B&K Precision 2552-2559 - Manual User Manual
Page 97

97
Figure 57 - Save/Rec Menu
To save setups to the oscilloscope’s internal memory, follow the steps
below:
For example: Save setup that set waveform display type to “Dots” to
internal memory.
1. Press the “SAVE/RECALL” button to enter the
“SAVE/RECALL” menu.
2. Press the “Type” option button to select “setups”.
3. Press the “Save to” option button to select “Device”.
4. Press the “Setup” option button to select “No.1”.
5. Press the “DISPLAY” button to enter the “Display” menu.
6. Press the “Type” option button to select “Dots”.
7. Press the “SAVE/RECALL” button to enter the
“SAVE/RECALL” menu.
8. Press the “Save” option button.
To Recall setup, follow steps below:
1. Press the “SAVE/RECALL” button to enter the
“SAVE/RECALL” display menu.
2. Press the “Type” option button to select “Setups”.
3. Press the “Save to” option button to select “Device”.
4. Press the “Setup” option button or turn the “Universal” knob
to select “No.1”.
5. Press the “Recall” option button.