“Trigger setup menu”.

4.

Press the “Holdoff” option button and turn the

“Universal” knob to change the holdoff time until the

waveform triggers steadily.

Signal Acquisition System

Shown below is the “ACQUIRE” button for entering the menu for

“Acquiring Signals”.

Table 29- Acquiring Signals Function Menu

Option

Setting

Description

Acquisition

Sampling

Use for sampling and accurately display

most of the waveform.

Peak Detect

Detect the noise and decrease the

possibility of aliasing.

Average

Use to reduce random or uncorrelated

noise in the signal display.

Averages

(4, 16, 32, 64,

128, 256)

Select number of averages.

Sinx/x

Sinx

x

Use sine interpolation.

Use linear interpolation.

Mode

Equ time

Real time

Set the Sampling mode to Equivalent

time.

Set the Sampling mode to Real time.